Fault code 1616: System Hardware Fault
Updated over a week ago

These faults apply to the following sungrow products:

  • SG30CX / SG33CX / SG40CX / SG50CX / SG110CX

  • SG2.0RS-S / SG2.5RS-S / SG3.0RS-S / SG3.0RS /SG3.6RS / SG4.0RS / SG5.0RS / SG6.0RS

  • SH3.0RS/SH3.6RS/SH4.0RS/SH5.0RS/SH6.0RS

  • SG3.0RT / SG4.0RT / SG5.0RT / SG6.0RT / SG7.0RT /SG8.0RT / SG10RT / SG12RT / SG15RT / SG17RT /SG20RT

  • SH5.0RT/SH6.0RT/SH8.0RT/SH10RT

  • SH5T/6T/8T/10T/12T/15T/20T/25T

  • S450S/S800S/S1600S

In the event of Fault Code 1616 being informed through the App, the following corrective measures shall be taken:

System Hardware Fault (Code 1616)

Fault name

System Hardware Fault (fault code: 1616)

Fault type

Alarm

Fault condition

System Internal Module Abnormal

Steps and method of troubleshooting

1. It is prohibited to disconnect the DC switch when the DC current is greater than 0.5 A when the fault occurs.

2. Disconnect the DC switch only when the inverter DC side current drops below 0.5 A.

3. It is prohibited to power up the inverter again. Please contact Sungrow Customer Service.


For further information, please download the user manual here.

This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.

The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.

  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.

  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.

  • Be familiar with local standards and relevant safety regulations of electrical systems.

  • Read this manual thoroughly and understand the safety instructions related to operations.