SHxxRS: Smart Meter Connection

1-phase hybrid inverters

Updated over a week ago

For installing the S100 (Smart Energy Meter) to the 1-Phase Hybrid inverters, the COM 2 port will be used and connected to the grid as follows:

  1. Pass the Power Phase Cable from the grid through the meter´s CT (current transformer) for it to measure the current flow. The communication cables A and B will communicate the meter device to the inverter.

  2. From the Smart meter device, the Grid´s Neutral (N) and Phase (L) cables are used to measure the Phase Voltage (L-N).

    Fig.1.

  3. The communication cables A and B are connected to the A2 and B2 ports from the inverter´s COM 2.

Fig.2.


For further information, please download the user manual here.

This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.

The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.

  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.

  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.

  • Be familiar with local standards and relevant safety regulations of electrical systems.

  • Read this manual thoroughly and understand the safety instructions related to operations.