Off-grid overvoltage (Code 064)

Fault name

Off-grid inverter overvoltage fault (fault code: 064)

Fault type

Fault

Fault condition

The effective value of inverter voltage is higher than the protection value under off-grid normal operation

Steps and methods of troubleshooting

Use a multimeter to measure the off-grid port voltage and compare it with the displayed value. If there is a big difference, it is judged that the sampling is abnormal, and it is recommended to replace the inverter.

Off-grid low frequency (Code 065)

Fault name

Off-grid port inverter low frequency fault (fault code: 065)

Fault type

Fault

Fault condition

The inverter frequency value is lower than the normal range under off-grid normal operation

Steps and methods of troubleshooting

If the fault remains, it is recommended to replace the inverter.

Off-grid high frequency (Code 066)

Fault name

Off-grid port inverter high frequency fault (fault code: 066)

Fault type

Fault

Fault condition

Inverter frequency value exceeds the standard under off-grid normal operation

Steps and methods of troubleshooting

If the fault remains, it is recommended to replace the inverter.

For further information, please download the user manual here.

This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.

The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.

  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.

  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.

  • Be familiar with local standards and relevant safety regulations of electrical systems.

  • Read this manual thoroughly and understand the safety instructions related to operations.

Did this answer your question?