Skip to main content
All CollectionsSHxxRS: 1 Phase Hybrid Systems (3-6kW and Battery)Troubleshoooting
Fault code and troubleshooting steps of SHxxRS 041 - 050
Fault code and troubleshooting steps of SHxxRS 041 - 050

Applicable to: SHxxRS series

Updated over a year ago

Leakage current sampling channel fault (Code 041)

Fault name

Leakage current sampling channel fault (fault code: 041)

Fault type

Failure shutdown

Fault condition

The sampling channel is abnormal (test the hardware when inverter starts up, not when inverter is in operation.)

Steps and method of troubleshooting

Repair by replacing the inverter.

Low ambient temperature (Code 043)

Fault name

Low ambient temperature (fault code: 043)

Fault type

Failure shutdown

Fault condition

The temperature in the machine is lower than -29°C for 1s

Steps and method of troubleshooting

1. Check whether the external ambient temperature is normal. Keep the ambient temperature higher than -25°C for 4s.

2. Check whether the power module is normal. If it is abnormal, please replace the power board.

If the power module is normal, it is recommended to replace the complete inverter.

Abnormal AC-current sampling channel (Code 048)

Fault name

Abnormal AC current sampling channel (fault code: 048)

Fault type

Fault shutdown

Fault condition

Sampling channel abnormality (detected when inverter starts, not detected during operation.)

Steps and methods of troubleshooting

It is recommended to replace the inverter.

For further information, please download the user manual here.

This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.

The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.

  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.

  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.

  • Be familiar with local standards and relevant safety regulations of electrical systems.

  • Read this manual thoroughly and understand the safety instructions related to operations.

Did this answer your question?