Skip to main content
All CollectionsCommunication DevicesLoggerX000 and COM100X
Description of Logger1000 Indicator Status
Description of Logger1000 Indicator Status

Applicable to : Data Logger1000B/A-EU

Updated over 2 months ago

Logger1000A-EU

Indicator (Mark)

LED Color

LED Status

Description

RUN indicator
(RUN)

Green

  1. Off

  2. Blink green

  1. Not connected to any external power supply.

  2. Normal operation.

RUN indicator
(RUN)

Red

  1. Blink red

  2. Steady red

  1. Device Alarm

  2. There is a fault with Logger1000

Network indicator (WLAN/4G)

Blue

  1. Off

  2. Steady on

  3. Blink/flashing

  1. No data communication

  2. Connected to WiFi/4G

  3. Data communication in progress

Logger1000B

Indicator (Mark)

LED Color

LED Status

Description

RUN indicator
(RUN)

Green

  1. Off

  2. Blink green

  1. Not connected to any external power supply.

  2. Normal operation.

RUN indicator
(RUN)

Red

  1. Blink red

  2. Steady red

  1. Device Alarm

  2. There is a fault with Logger1000

Network indicator (WLAN)

Blue

  1. Off

  2. Steady on

  3. Blink/flashing

  1. No data communication

  2. Connected to WiFi

  3. Data communication in progress


For further information, please download the user manual accordingly:

This manual is intended for professional technicians who are responsible for installation, operation, maintenance and troubleshooting of inverters, and users who need to check inverter parameters. The inverter must only be installed by professional technicians.

The professional technician is required to meet the following requirements:

  • Know electronic, electrical wiring and mechanical expertise, and be familiar with electrical and mechanical schematics.

  • Have received professional training related to the installation, commissioning and troubleshooting of electrical equipment.

  • Be able to quickly respond to hazards or emergencies that occur during installation, commissioning and troubleshooting.

  • Be familiar with local standards and relevant safety regulations of electrical systems.

  • Read this manual thoroughly and understand the safety instructions related to operations.

Did this answer your question?